Tissue Processor
Available on Backorder
Product Enquiry
YD-14 Bench-Top Linear Closed Tissue Processor – Dual-Basket Automatic Dehydration & Paraffin Embedding System
Enhance your laboratory’s productivity and sample quality with the YD-14 Linear Closed Tissue Processor, a compact benchtop tissue processor designed for fully automated tissue dehydration and paraffin infiltration. With an intelligent dual-basket system, this high-throughput unit allows simultaneous processing of two sample batches, reducing turnaround times and maximizing efficiency.
Ideal for pathology labs, clinical diagnostics, university research, and biomedical institutions, the YD-14 delivers precise and consistent performance with modern safety features and advanced reagent protection.
Key Features
- Automated Dual-Basket Processing
Includes 14 stations (10 reagent + 4 paraffin) that can simultaneously operate two tissue baskets independently—each with its own programmable settings. - Closed System Design for Reagent Protection
All paraffin and reagent tanks are sealed to prevent evaporation and preserve reagent integrity. Includes an ion purification system to reduce solvent odors and lab pollution. - Auto-Locating & Memory Function
Intelligent system memorizes the starting position of each program to avoid misalignment. Each cylinder is individually positioned to ensure high accuracy. - User-Friendly Touchscreen Programming
Easily manage station time, temperatures, and dripping intervals using the intuitive touchscreen interface. Supports daily, weekend, and weekly programmable cycles. - Dry Heating Paraffin Cylinders
Safe and efficient dry heat system eliminates water-related failures such as corrosion, leakage, and electric faults. - Cylinder Jam Safety Alert
In the event of a jam, the system automatically stops and issues an alarm to protect tissue samples and internal mechanisms. - Flexible Program Editing
Modify steps within a saved program without needing to recreate the entire process—saving time and increasing flexibility. - USB Emergency Power Connector
Equipped with an external USB power input (power pack required) to maintain functionality during outages for up to 10 hours, preventing tissue dehydration.
Technical Specifications
Specification | Details |
---|---|
Cylinders | 14 total (10 reagent + 4 paraffin) |
Tissue Baskets | 2 (independent and simultaneous operation) |
Station Capacity | 1500 ml (Supports 300+ samples or 120 cassettes) |
Temperature Range | 0℃ ~ 99℃ |
Time per Cylinder | 1 min ~ 99 min 59 sec |
Programmable Cycles | 9 storable programs |
Basket Lift & Rest Time | 30 seconds |
Basket Agitation Frequency | 4 times every 10 minutes |
Power-On Delay Setting | Up to 99 hours 59 minutes |
Power Requirement | ≤ 900W |
Voltage Options | 220V/50Hz or 110V/60Hz |
Dimensions (W × D × H) | 140 × 50 × 55 cm |
Applications
This advanced tissue processing system is the ideal solution for:
- Histopathology & Anatomic Pathology Labs
- Medical Research Facilities
- Veterinary Diagnostics
- Teaching Hospitals & Universities
Whether used for routine biopsies or complex research specimens, the YD-14 benchtop tissue processor ensures high-throughput, reliable, and safe sample processing.
Included Accessories
- 1 × Power Cable
- 2 × Fuses
Looking for a powerful, programmable, and compact tissue processor? The YD-14 Linear Closed Tissue Processor is the smart choice for modern labs that demand performance, precision, and safety. Contact us now for pricing, availability, or bulk inquiries.